Beskrivelse
[Please be sure to read the instruction manual]
[Generic Name] Home Low-Frequency Therapy Device
[Product Name] OMRON Low-Frequency Therapy Device HV-F030 Series
[Contraindications/Prohibitions] • Never use this product in conjunction with the following electrical medical devices: (1) Implantable electrical medical devices such as pacemakers (2) Life-sustaining electrical medical devices such as artificial hearts and lungs (3) Wearable electrical medical devices such as electrocardiographs ▶ Doing so may cause malfunction of these electrical medical devices, resulting in serious injury or death. • Do not use near the heart, chest, above the neck (including the head and mouth), genitals, or areas with skin conditions. • Do not use the dedicated pad (for joints) in a way that pinches internal organs. ▶ Doing so may result in an accident or poor health. • Do not use this product in conjunction with other medical devices, use two or more units of this product simultaneously, or use it in conjunction with compresses or liniments (including spray cans). ▶ May cause you to feel unwell or become unwell. • Do not use in humid areas or while bathing. ▶ May cause electric shock. • The following people should consult a doctor before using this product: (1) People receiving medical treatment or experiencing any physical abnormalities (2) People with malignant tumors (3) People with cardiac or neurological abnormalities (4) Pregnant women or women who have just given birth (5) People with a body temperature of 38°C or higher (fever stage) (Example 1: During a period of severe acute symptoms (fatigue, chills, blood pressure fluctuations, etc.); Example 2: When feeling weak) (6) People with infectious diseases (7) People with skin sensory impairments or abnormalities (8) People with acute (painful) illnesses such as spinal fractures, sprains, or pulled muscles (9) People requiring rest (10) People taking medication (11) People with abnormal blood pressure (12) People with limb disabilities (13) People unable to express their own will (14) People with sensory impairments due to severe peripheral circulatory disorders such as diabetes (15) People with low temperatures (16) People with poor circulation (17) People who do not see any results even after using the device for a while (18) People whose skin does not respond to the pads (19) People with metal objects embedded in their bodies ▶ Continued use may result in an accident or poor health. • Do not connect the lead cord plug to any location other than the lead cord plug socket on the device. ▶ Doing so may result in electric shock or an accident. • Do not disassemble, repair, or modify the device. ▶ Doing so may result in fire, malfunction, or an accident. • Do not use for any purpose other than medical treatment. • Do not use the pad if the surface is chipped or broken. • Do not use the pad if the adhesive surface has peeled off. ▶ Doing so may result in an accident, trouble, or malfunction. • Do not allow children to use the device or play with the device or pads. Also, do not allow them to climb on or stand on the device. ▶ Doing so may result in an accident, injury, poor health, or malfunction. • Do not allow people who are unable to express themselves, people with physical disabilities, or people who require assistance to use the device alone. ▶ Failure to do so may result in accidents, injuries, or poor health. • Do not use while sleeping. ▶ Failure to do so may result in malfunction. The pads may also stick to unexpected places, causing poor health. • Do not use while driving a car or operating dangerous machinery. ▶ Strong stimulation may lead to accidents or other problems. • Do not bend or fold the pads forcefully. ▶ Failure to do so may result in electric shock or an accident. • Do not use if the lead cord is damaged, such as a broken cord or a broken plug. Purchase a separate item. ▶ Failure to do so may result in electric shock, short circuit, or fire.
[Usage Precautions] • Do not use during exercise. ▶ Failure to do so may result in an accident. • Do not use if you feel pain immediately after exercise. ▶ Failure to do so may result in an accident or injury. • If you experience any physical abnormalities or skin irritation such as eczema, redness, or itching, discontinue use immediately. ▶ Consult a doctor and follow their instructions. • If the device stops working or you notice any abnormalities, turn off the power immediately and contact the Omron Customer Service Center. ▶ Doing so may result in accidents, problems, or malfunctions due to overheating or short circuits. • Do not leave the pads attached to the affected area. ▶ Doing so may cause skin inflammation. • If you need to change the pads to a different area during treatment, be sure to turn off the power before doing so. • Do not use the pads while they are in contact with metal objects such as belts or necklaces. ▶ You may receive a strong shock. • Do not insert/remove the lead cord or attach the pads with wet hands. • Do not attach the pads to wet areas. ▶ Doing so may result in electric shock or accidents. • Do not use the pads in one area for long periods of time (60 minutes or more) continuously. ▶ This may cause muscle fatigue, poor physical condition, or severe pain. • Make sure the lead cord, main unit, and pads are connected correctly before use. ▶ Improper connection may result in electric shock, accidents, or malfunctions. • Attach the pads correctly. ▶ Attaching the pads incorrectly may result in accidents or poor physical condition. • Do not attach pads to areas where deodorant sheets or sprays to reduce sweating have been used, or where lotion, oil, sweat, insect repellent spray, or sunscreen has been applied, or where the pads are not clean. ▶ The adhesive strength of the pads may decrease. • When attaching the pads, be careful not to get the lead cord tangled around your neck. ▶ This may result in accidents or injury. • When removing the lead cord from the main unit, always hold the lead cord plug and unplug it, not the lead cord itself. ▶ This may result in electric shock, accidents, or malfunctions. • If the adhesive strength of the pads decreases, clean them. If the adhesiveness of the pads still does not return, please purchase the optional pads. ▶ Using the pads as is may result in an accident or poor health. • Do not share pads with other people. ▶ Doing so may result in infection or skin inflammation. • Store the pads attached to the pad holder. • Always keep the pads clean. ▶ Improper storage may result in damage to the pads. • When using this product, do not use any products other than those designated for use. ▶ Doing so may result in an accident or malfunction.
[Product Specifications] Brand Name: OMRON Low-Frequency Therapy Device HV-F030 Series Medical Device Certification Number: 304AABZX00080000 Category: Machinery & Equipment 78, Home Electric Therapy Device Generic Name: Home Low-Frequency Therapy Device Medical Device Classification: Controlled Medical Device Product Code: HV-F030 Power Supply: DC 3.0 V (two AAA alkaline batteries) Battery Life: Approximately 4 months (15 minutes of continuous use once per day) Rated Output Voltage: Maximum approximately 80 V Maximum Output Current: 10 mA or less Fundamental Frequency: Approximately 1 to 132 Hz Maximum Pulse Width: 150 μs Rated Time: 15 minutes Power Consumption: 0.1 W Service Life (Based on our self-certified data): Main unit (approximately 5 years), Pads (approximately 30 uses) *Based on standard usage (15 minutes per day, 3 days per week) Usage Environment: +10 to +40°C / 30 to 85% RH (non-condensing) / 700 to 1060 hPa Storage Environment: 0 to +40°C / 30 to 85% RH (non-condensing) Weight: Main unit: Approx. 100 g (including batteries) Operating Principle: Utilizing the nerve and muscle response to low-frequency electricity, a weak pulse current is passed through the skin surface, utilizing the resulting physiological effects to treat the affected area. Dimensions: Main unit: Approx. 52 (W) x 112 (H) x 25 (D) mm HV-SPAD-MU. Pad: Approx. 99 (W) x 166 (H) x 1 (D) mm HV-SPAD-JO Pad: Approx. 40 (W) x 98 (H) x 1 (D) mm Composition of parts in direct contact with the body: Acrylic resin, glycerin, water Auto Power-Off: The unit will automatically turn off in the following cases: • When 15 minutes of treatment has finished • When the battery is depleted • When the pads are not properly attached or have come off • When 3 minutes have passed since powering on without treatment starting
[Name of Manufacturer and Distributor] Manufacturer: Omron Healthcare Co., Ltd. Tel: 0120-30-6606 (Omron Customer Service Center)
[Purpose of Use or Effects/Efficacy] Relieves stiff shoulders, prevents atrophy of paralyzed muscles, and provides a massage effect. For general household use. Specially Designated Medical Device Certification Number: 302AABZX00011000 Dimensions: Approx. 52 (W) x 112 (H) x 25 (D) mm Weight: Approx. 100 g (including batteries) Accessories: Main unit, dedicated pads (for muscles) HV-SPAD-MU, dedicated pads (for joints) HV-SPAD-JO, electrode cord HV-CODE-BW, pad holder, storage case, trial batteries (2 AAA alkaline batteries), instruction manual (with quality guarantee)